Download e-book for kindle: 13 A Plugs, Socket-outlets and Adaptors: Specification for by British Standards Institution

By British Standards Institution

ISBN-10: 058022306X

ISBN-13: 9780580223068

Show description

Read Online or Download 13 A Plugs, Socket-outlets and Adaptors: Specification for 13 A Switched and Unswitched Socket-outlets BS 1363 PDF

Best electronics: telecommunications books

Data Warehousing and Data Mining for Telecommunications - download pdf or read online

. .first complete consultant to supply useful, step-by- step instructions for designing and supplying information- warehousing and mining purposes in a telecommunications surroundings.

Get Communication Networking: An Analytical Approach PDF

Today simulation modeling is the preferred approach for figuring out the habit of advanced networks. With the supply of particularly reasonably cheap advertisement programs for doing simulations, community designers and community functionality analysts can now achieve perception into the collective habit of community units corresponding to servers, routers, and switches with a excessive measure of accuracy.

Professional Feature Writing (Routledge Communication - download pdf or read online

This article deals the fundamentals of stories media characteristic writing and publications stimulated newbies down the suitable course towards luck as expert characteristic writers. This fourth variation provides complex writers and newshounds a radical examine newspaper, journal, publication, and on-line guides, with emphasis on day-by-day newspapers and patron magazines.

Additional resources for 13 A Plugs, Socket-outlets and Adaptors: Specification for 13 A Switched and Unswitched Socket-outlets BS 1363

Sample text

25 mm2 flexible cord as given in Table 27 of BS 6500:2000. Non-rewirable accessories are tested as delivered. The free end of the flexible cord which is approximately 2 250 mm long is fixed to a wall at a height 0 of 400 –10 mm above the floor, as shown in Figure 22. The specimen is held so that the cable is approximately horizontal and then it is allowed to fall on to a concrete floor eight times, the flexible cord being rotated through approximately 45° at its fixing each time. 4b) and Clause 15 and Clause 16.

X Example 3 Example 3 Condition: Rule: Path under consideration includes a V-shaped groove with a width greater than “X” mm. Clearance is the “line of sight” distance. Creepage path follows the contour of the groove but “short circuits” the bottom of the groove by an “X” mm link. --`,,`-`-`,,`,,`,`,,`--- 32 Copyright British Standards Institution Provided by IHS under license with BSI No reproduction or networking permitted without license from IHS © BSI 9 October 2003 Not for Resale BS 1363-2:1995 --`,,`-`-`,,`,,`,`,,`--- Example 4 Example 4 Condition: Rule: Path under consideration includes a rib.

After 5 000 flexings, socket-outlets are turned through 90° ± 5° about the cord entry centreline. NOTE A flexing is one movement through 90°, either backwards or forwards. During the test there shall be no interruption of the current passing through the conductors and no short circuit between them. After the test the sample shall show no damage except that breakage of no more that 10 % of the total number of conductor strands in any core is ignored provided they have not pierced the insulation.